Now showing items 1-4 of 4

    • Mathew, Ajay; Tokuyama, Shinichiro; Masaki, Shakuda; Subramani, Elumalai (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2018)
      The process gas compressor is the most critical unit in ethylene plants and several types of contamination can often foul the compressor flow path and plant production is significantly lost. In order to prevent this ...
    • Nishiyama, Kenichi; Jain, Mayank; Subramani, Elumalai (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2018)
      Fatigue failure of Governing Valve Linkage Rod end bearing and wear marks on several parts was observed on a extraction steam turbine (driving a centrifugal compressor) after it was in service for more than 9 year. The top ...
    • Nishiyama, Kenichi; Jain, Mayank; Subramani, Elumalai (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2018)
      Fatigue failure of Governing Valve Linkage Rod end bearing and wear marks on several parts was observed on a extraction steam turbine (driving a centrifugal compressor) after it was in service for more than 9 year. The top ...
    • Tokuyama, Shinchiro; Mohit, Goenka; Nakaniwa, Akihiro; Mathew, Ajay; Subramani, Elumalai (Turbomachinery Laboratory, Texas A&M Engineering Experiment Station, 2018)
      This paper introduces the development of new concept of on-line wash oil injection system which includes the optimization of quantity of washing oil, location of injection nozzles, direction of nozzle entry, hole size as ...